Ad20p 1230e
AD20P-1230E pump implementation via CS-IO404 Modbus relay module.
Controls an AD20P-1230E 12V submersible pump through a CS-IO404 4-channel relay module on the MODBUS RTU bus. Includes interactive calibration and test procedures accessible via the setup utility.
CS_IO404_Based_AD20P_1230E
¶
Bases: Pump, MODBUSInterface, HasSetupFunctionsMixin
AD20P-1230E pump controlled via a CS-IO404 Modbus relay.
Converts dosage requests (ml) to timed relay activations using linear calibration parameters. The relay module is addressed via MODBUS RTU.
Attributes:
| Name | Type | Description |
|---|---|---|
relay_address |
MODBUS device address of the CS-IO404 module (1-247). |
|
coil_number |
Output coil index on the relay module (0-3). |
|
calibration_save_function |
Callback to persist new calibration data. |
Source code in pt/controller_3/src/plant_controller/pumps/ad20p_1230e.py
23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 | |
__init__(bus, db_save_function, calibration_parameters, calibration_save_function, relay_address, coil_number)
¶
Initialize the pump with relay addressing and calibration.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
bus
|
MODBUS
|
MODBUS bus instance. |
required |
db_save_function
|
Callable[[Datapoint | list[Datapoint]], None]
|
Async function to persist watering events. |
required |
calibration_parameters
|
dict[str, Any]
|
Dict with 'slope' and 'offset' keys. |
required |
calibration_save_function
|
Callable
|
Callable(slope, offset) to persist new calibration values after the calibration procedure. |
required |
relay_address
|
int
|
MODBUS address of the CS-IO404 (1-247). |
required |
coil_number
|
int
|
Relay output index (0-3). |
required |
Raises:
| Type | Description |
|---|---|
ValueError
|
If coil_number or relay_address is out of range. |
Source code in pt/controller_3/src/plant_controller/pumps/ad20p_1230e.py
doseage_to_time(dosage)
¶
Convert a dosage in ml to pumping duration in seconds.
Uses the linear model: time = slope * dosage + offset.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
dosage
|
int
|
Desired water amount in milliliters. |
required |
Returns:
| Type | Description |
|---|---|
float
|
Pumping duration in seconds. |
Source code in pt/controller_3/src/plant_controller/pumps/ad20p_1230e.py
pumping_callback(dosage)
async
¶
Pump the specified dosage and record the watering event.
Parameters:
| Name | Type | Description | Default |
|---|---|---|---|
dosage
|
int
|
Amount to pump in milliliters. |
required |
Source code in pt/controller_3/src/plant_controller/pumps/ad20p_1230e.py
calibrate()
async
¶
Interactive calibration procedure for determining pump flow rate.
Guides the user through multiple pump cycles at different durations, collecting volume measurements to compute a linear fit (slope and offset) for the dosage-to-time relationship. Results are saved via the calibration_save_function.
Source code in pt/controller_3/src/plant_controller/pumps/ad20p_1230e.py
120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 | |
test_pump()
async
¶
Interactive test: pump a user-specified dosage to verify calibration.
Source code in pt/controller_3/src/plant_controller/pumps/ad20p_1230e.py
setup_functions()
¶
Return available setup actions for this pump.
Returns:
| Type | Description |
|---|---|
dict[str, dict[str, any]]
|
Dict with 'calibrate' and 'test' entries. |